APlus M33 80K ~ 600KVA

APlus is htel modular online UPS that provides high-efficiency value with a compact footprint and a flexible and scalable architecture, able to reach up to 600KW with only 10 modules. Hot-swappable modular design and built-in maintenance bypass switch enabling the system to be upgraded or repaired without powering down a mission-critical connected load.

  Main Features
  • High efficiency online double conversion technology
  • High scalability
  • Unity output power factor
  • Modular design lowers MTTR
  • N+1 or N+X parallel redundancy for power guarantee
  • Ease of installation and maintenance
  • Flexible battery configuration adapts different applications
  • Highly reliable operation with redundant power supply in STS
  • User-adjustable charging current
  • High overload capability



  MODELM33-90KM33-120KM33-80KL
M33-120KL
M33-120KL
M33-180KL
M33-200KLM33-210KLM33-300KL
  PHASE3-phase in / 3-phase out
  CABINET CAPACITY*90 KW120 KW80 KW or 120 KW120 KW or 180 KW200 KW210 KW300 KW
  BATTERY TYPEBuilt-in BatteryExternal Battery
  POWER MODULE CAPACITY30KVA / 30KW30KVA / 30KW or 20KVA / 20KW20kKVA / 20KW30KVA / 30KW30KVA / 30KW
  MAX. POWER MODULE NO.344610810
  MAX. BATTERY SET NO.**35-----
  INPUT
  Nominal Voltage3 x 380VAC/400VAC/415VAC (3Ph+N)
  Voltage Range305 ~ 478 VAC at 100% load; 208 ~ 304VAC at <70% load
  Nominal Frequency50/60Hz (Auto Sensing)
  Frequency Range40Hz ~70Hz
  Power Factor> 0.99 @ 100% Load , >0.98 @ 50% Load
  Harmonic Distortion (THDi)< 3% @ 100% load
  OUTPUT
  Nominal Voltage3 x 380VAC/400VAC/415VAC (3Ph+N)
  Voltage Regulation(Steady state)± 1% Typical (balanced load) ;  ± 2% Typical (imbalanced load)
  Nominal Frequency50/60Hz
  Frequency Range(Synchronized)46Hz ~ 54Hz or 56Hz ~ 64Hz
  Overload Capability1 hour for 110%, 10 mins for 125%,; 1 min for 150%, 200ms for >150%
  Harmonic Distortion 2% THD (Linear Load) ;  4% THD (Non-linear Load)
  EfficiencyUp to 94.5%
  BATTERY / CHARGER
  Nominal Voltage+/- 216V (12V x 36 pcs)
  Maximum Voltage+/- 240V (12V x 40 pcs)
  Minimum Voltage+/- 192V (12V x 32 pcs)
  Float Charging Voltage2.25V / Cell
  Boost Charging Voltage2.35V / Cell
  Temperature CompensationYes

  Maximum Charging Current

  (Per Power Module)

8A

8A for 30KW power module

 6A for 20KW power module

6A8A
  PHYSICAL

  Cabinet Dimension 

  (D x W x H) mm

1100 x 600 x 14751100 x 600 x 20101100 x 600 x 14751100 x 600 x 14751100 x 600 x 2010
  Net Weight (Kg)675932335 or 333437.5 or 434.5611549620
  ENVIRONMENT
  Operating Temperature0 ~ 40°C
  Relative Humidity0 ~ 95% non-condensing
  Altitude<1000m for Nominal power
  IP ProtectionIP 20
  MANAGEMENT
  Smart RS-232 / USBSupports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux and MAC
  Optional SNMPPower management from SNMP manager and web browser
  STANDARDS
  SafetyIEC/EN 60950-1; IEC/EN 62040-1
  EMCIEC/EN 62040-2 Category C3


  *When temperature is above 30, the output power factor will be de-rated, 0.9 at 31~35and 0.8 at 36~40

  ** One battery module contains 10 pcs of 12V/7Ah or 12/9Ah sealed lead acid batteries in one tray. One complete battery set contains 4 battery modules. 

  ***If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.

  Main Features
  • 50KW/60KW for single power module in 3U
  • Single 42U cabinet up to 600KW
  • Two cabinet size for 300KW: 1065mm and 850mm
  • N+1 or N+X parallel redundancy for power guarantee
  • Supports horizontal expansion by 1+1 cabinet parallel operation
  • Hot-swappable modular design decreases MTTR 
  • High scalability
  • Built-in maintenance bypass switch for easy maintenance without interruptible
  • High efficiency double conversion online UPS
  • Flexible battery configuration and adjustable charging current
  • High overload capability
  • Power walk-in function
  • Built-in dynamic password protection
  • Built-in ultra communication slot



  MODEL

M33-50S-300KL

 (PM-50) S

M33-50-300KL 

(PM-50)

M33-50-350KL 

(PM-50)

M33-50-400KL 

(PM-50)

M33-50-500 KL 

(PM-50)

  PHASE3-phase in / 3-phase out
  CABINET CAPACITY*300KW300KW350KW400KW500KW
  BATTERY TYPEExternal Battery
  ONE POWER MODULE CAPACITY50KVA/50KW
  MAX. POWER MODULE NO.667810
  INPUT
  Nominal Voltage3 x 380/400/415 VAC (3Ph+N)
  Voltage Range-20% ~ +15%
  Nominal Frequency50/60Hz (Auto Sensing)
  Frequency Range40Hz ~70Hz
  Power Factor> 0.99 @ 100% Load , >0.98 @ 50% Load
  Harmonic Distortion (THDi)< 4% @ 100% load
OUTPUT
  Nominal Voltage3 x 380/400/415 VAC (3Ph+N)
  Voltage Regulation(Steady state) ± 1% Typical (balanced load) ;  ± 2% Typical (unbalanced load)
  Nominal Frequency50/60Hz
  Frequency Range(Synchronized)46Hz ~ 54Hz or 56Hz ~ 64Hz
  Overload Capability1 hour for  110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150%
  Harmonic Distortion 2% THD (Linear Load) ;  4% THD (Non-linear Load)
  Efficiency95.5%
  BATTERY / CHARGER
  Nominal Voltage+/- 192V ~ +/- 240V (Selectable)
  Maximum Voltage+/- 240V (12V x 40 Pcs)
  Minimum Voltage+/- 192V (12V x 32 Pcs)
  Floating Charge Voltage2.28V / Cell   (2.25 ~2.33 Selectable)
  Boost Charging Voltage2.35V/Cell
  Temperature CompensationYes

  Maximum Charging Current 

  (Per Power Module)

12A (Adjustable)
  PHYSICAL
  Cabinet Dimension (D x W x H) mm850 x 600 x 20001065 x 600 x 20001065 x 600 x 20001065 x 1000 x 20001065 x 1000 x 2000
  Net Weight (Kg)4905456549321020
  ENVIRONMENT
  Operating Temperature0 ~ 40°C
  Relative Humidity0 ~ 95% non-condensing
  Altitude*<1000m for Nominal power
  IP ProtectionIP 20
  MANAGEMENT
  Smart RS-232 / USBSupports Windows® Family, Linux and MAC
  Optional SNMPPower management from SNMP manager and web browser
  STANDARDS
  SafetyIEC/EN 62040-1
  EMCIEC/EN 62040-2 Category C3


      ***  If the UPS is installed or used in a placewhere the altitude is above than 1000m, the output power must be derated one percent per 100m.


  ModelDescriptionDimension DxWxH(mm)Weight (kg)
  PM-503P/3P 50KVA/50KW Power Module750 x 438 x 130 (3U)44
  PM-50 (S)3P/3P 50KVA/50KW Power Module650 x 438 x 130 (3U)36


  MODELM33-60-120KLM33-60-180KLM33-60-300KLM33-60-420KLM33-60-480KLM33-60-600KL
  PHASE3-phase in / 3-phase out
  CABINET CAPACITY*120 KW180 KW300 KW420KW480KW600KW
  BATTERY TYPEExternal Battery
  ONE POWER MODULE CAPACITY60KVA / 60KW
  MAX. POWER MODULE NO.2357810
  INPUT
  Nominal Voltage3 x 380/400/415 VAC (3Ph+N)
  Voltage Range-30% ~ +20%
  Nominal Frequency50/60Hz (Auto Sensing)
  Frequency Range40Hz ~70Hz
  Power Factor> 0.99 @ 100% Load , >0.98 @ 50% Load
  Harmonic Distortion (THDi)< 3% @ 100% load
  OUTPUT
  Nominal Voltage3 x 380/400/415 VAC (3Ph+N)
  Voltage Regulation(Steady state)± 1% Typical (balanced load) ; ± 2% Typical (unbalanced load)
  Nominal Frequency50/60Hz
  Frequency Range(Synchronized)46Hz ~ 54Hz or 56Hz ~ 64Hz
  Overload Capability1 hour for  110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150%
  Harmonic Distortion2% THD (Linear Load) ; 4% THD (Non-linear Load)
  Efficiency96%
  BATTERY / CHARGER
  Nominal Voltage+/- 192V ~ +/- 240V (Selectable)
  Maximum Voltage+/- 240V (12V x 40 Pcs)
  Minimum Voltage+/- 192V (12V x 32 Pcs)
  Floating Charge Voltage2.28V / Cell   (2.25 ~2.33 Selectable)
  Boost Charging Voltage2.35V/Cell
  Temperature CompensationYes

  Maximum Charging Current 

  (Per Power Module)

18A (Adjustable)
PHYSICAL

  Cabinet Dimension 

  (D x W x H) mm

1100 x 600 x 14751100 x 600 x 14751100 x 600 x 20101100 x 600 x 20101065 x 1000 x 20001065 x 1000 x 2000
  Net Weight (Kg)3083525166549321020
  ENVIRONMENT
  Operating Temperature0 ~ 40°C
  Relative Humidity0 ~ 95% non-condensing
  Altitude*<1000m for Nominal power
  IP ProtectionIP 20
  MANAGEMENT
  Smart RS-232 / USBSupports Windows® Family, Linux and MAC
  Optional SNMPPower management from SNMP manager and web browser
  STANDARDS
  SafetyIEC/EN 62040-1
  EMCIEC/EN 62040-2 Category C3


       ***  If the UPS is installed or used in a placewhere the altitude is above than 1000m, the output power must be derated one percent per 100m.


  ModelDescriptionDimension DxWxH(mm)Weight (kg)
  PM-603P/3P 60KVA/60KW Power Module750 x 438 x 130 (3U)44


APlus M33 80K ~ 600KVA
APlus is htel modular online UPS that provides high-efficiency value with a compact footprint and a flexible and scalable architecture, able to reach up to 600KW with only 10 modules. Hot-swappable modular design and built-in maintenance bypass switch enabling the system to be upgraded or repaired without powering down a mission-critical connected load.
Long press to look detail
Long by picture save/share

APlus M33 80K ~ 600KVA

INQUIRY

enquiry form:

  • Please enter the verification code

enquiry content:


You have no items to require

Copyright @ 2021 Honyis Power Solutions Co., Ltd. All Rights Reserved

 

 粤公网安备 44030702003778号      ICP备2021024839号-1

let's chat now
添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了
粤ICP备2021024839号-1