Galleon T33 10K ~ 200KVA

Galleon T33 provides better output power factor up to 1.0 with higher performance and efficiency for critical applications. It's smae as Galleon series with programmable power management outlets which can extend available battery time to critical devices by shutting down unnecessary devies. This Galleon T33 series is also suitable for laser printer and ultrasound system load.

  Main Features ( 10KVA ~ 80KVA )
  • DSP technology guarantees high performance
  • Output power factor 1.0
  • Pluggable power module design
  • Front access design for easy maintenance
  • Active power factor correction in all phases
  • Emergency power off function (EPO)
  • Dual AC inputs
  • Parallel operation up to 4 units with common battery
  • Power walk-in function while parallel operation
  • Generator compatible
  • Adjustable battery numbers
  • Maintenance bypass available
  • 3-stage extendable charging design for optimized battery performance
  • Optional isolation transformer offers full isolation and complete common mode noise rejection


  Main Features ( 100KVA ~ 200KVA )
  • Power walk-in function 
  • Dual-mains inputs
  • Built-in 4 switches including Mains input, bypass input, output and maintenance bypass switch
  • Flexible battery configuration and adjustable charging current
  • Output power factor 1 
  • Active power factor correction in all phases
  • Built-in 7" touch LCD screen for comprehensive information 
  • Emergency power off function(EPO) 
  • Generator compatible
  • 50Hz/60Hz frequency converter mode





  MODELT33-10K (L)*T33-15K(L)T33-20K(L)*T33-30K(L)*T33-40K (L)T33-60KLT33-80KL
  PHASE3-phase in / 3-phase out
  CAPACITY10KVA /10KW15KVA/15KW20KVA/20KW30KVA/30KW40KV /40KW60KVA /60KW80KVA/80KW
  PARALLEL CAPABILITYup to 6 units in parallel
  INPUT
  Nominal Voltage3 x 380/400/415 VAC (3Ph+N)
  Voltage Range-30% ~ +20%
  Frequency Range40~70 Hz
  Power Factor 0.99  @ 100% Load
  Harmonic Distortion (THDi)< 3% at full linear load
  OUTPUT
  Output Voltage3 x 360*/380/400/415 VAC (3Ph+N)
  AC Voltage Regulation (Batt. Mode)± 1%
  Frequency Range (Synchronized Range)46~54Hz or 56~64Hz
  Frequency Range (Batt. Mode)50/60 Hz ± 1%
  Current Crest Ratio3:1 (max.)
  Harmonic Distortion 1 % THD (Linear Load) ;  3 % THD (Non-linear Load)
  Transfer Time  AC Mode to Batt. ModeZero
  Inverter to BypassZero
  Waveform (Batt. Mode)Pure Sine wave
  Overload Capability100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% or 400ms
  BYPASS
  Nominal Voltage3 x 380/400/415 VAC (3Ph+N)
  Voltage Range-30% ~ +20% (Adjustable)
  Frequency Range (Synchronized Range)46~54Hz or 56~64Hz
  Overload Capability> 130% 1 minute (default), Continously working until breaker protection (optional)
  EFFICIENCY
  AC Mode96.0%
  ECO Mode99.0%
  Battery Mode96.0%
  BATTERY
  Standard Model  Battery Type12 V/9 Ah12 V/9 Ah12 V/9 Ah12 V/7 Ah12 V/9 AhN/A
  Numbers(10+10) pcs(16+16) pcs(16+16) pcs(16+16) pcs x 2 strings
  Typical Recharge Time9 hours recover to 90% capacity
  Charging Current (max.)1A ~ 12A (Adjustable)

1A ~ 16 A

(Adjustable)

  Charging Voltage+/-136.5VDC±10%+/-218 VDC ± 10%
  Long-run Model  Battery TypeDepending on the applications
  Numbers+/- 10 pcs+/-16 pcs ~ +/- 20 pcs (Adjustable)
  Charging Current (max.)1A ~ 12A (Adjustable)

1A ~ 16 A

(Adjustable)

2A ~ 24 A
(Adjustable)
2A ~ 32A
(Adjustable)
  Charging Voltage

+/-136.5VDC±10%

+/-13.65V x N (N=16~20)
  INDICATORS
 LCD PanelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
  PHYSICAL
  Standard Model  Dimension,DxWxH (mm)630 x 250 x 826815 x 300 x 1000N/A
  Net Weight (kgs)124139225250
  Long-run Model  Dimension,DxWxH (mm)630 x 250 x 826815 x 300 x 1000790 x 360 x 1010
  Net Weight (kgs)28436067108113
  ENVIRONMENT
  Operation Temperture0-40°C
  Operation Humidity< 95% and non-condersing
  Altitude**0 ~ 1500m at full load
  Noise LevelLess than 60 dB @1 MeterLess than 63 dB @1 MeterLess than 65 dB @1 Meter
  MANAGEMENT
  Smart RS-232 / USBSupports Windows2  2000/2003/XP/Vista/2008, Windows2  7/8/10, Linux and MAC
  Optional SNMPPower management from SNMP manager and web browser

       

      *  If output voltage is set as 3 x 360VAC, the output power of the unit will be de-rated to 90%.

      ** If the UPS is installed or used in a place where the altitude is higher than maximum height, the output power will be derated 1% per 100m.

  MODELT33-100KLT33-120KLT33-180KLT33-200KL
  PHASE3-phase in / 3-phase out
  CABINET CAPACITY100KVA/100KW120KVA/120KW180KVA/180KW200KVA/200KW
  BATTERY TYPEExternal Battery
  PARALLEL CAPABILITY4
  INPUT
  Nominal Voltage3 x 380/400/415 VAC (3Ph+N)
  Voltage Range110-300 VAC @ 50% load; 176-276 VAC @100% load
  Nominal Frequency50/60Hz (Auto sensing)
  Frequency Range40Hz ~70Hz
  Power Factor 0.99  @ 100% load
  Harmonic Distortion (THDi)< 4% at full linear load
  OUTPUT
  Nominal Voltage3 x 380/400/415 VAC (3Ph+N)

  Voltage Regulation 

  (Steady state)

 ± 1% Typical (balanced load)
 ± 2% Typical (unbalanced load)
  Nominal Frequency50/60Hz

  Frequency Range

  (Synchronized range)

46Hz ~ 54Hz or 56Hz ~ 64Hz
  Overload Capability 110% for 1 hour, 111% ~ 125% for 10 mins, 126%~150% for 1 min and >150% for 200ms
  Harmonic Distortion 2% THD (Linear Load) ;  4% THD (Non-linear Load)
  EFFICIENCY
  AC Mode95.5%
  ECO Mode98.5%
  Battery Mode94.5%
  BYPASS
  Nominal Voltage3 x 380/400/415 VAC (3Ph+N)
  Voltage Range-30% ~ +20%
  Frequency Range46Hz ~ 54Hz or 56Hz ~ 64Hz
  Overload Capability 110% for 1 hour, 111% ~ 125% for 10 mins, 126%~150% for 1 min and >150% for 200ms
  BATTERY / CHARGER
  Nominal Voltage+/- 192V ~ +/- 240V (Selectable)
  Maximum Voltage+/- 240V (12V x 40 Pcs)
  Minimum Voltage+/- 192V (12V x 32 Pcs)
  Floating Charge Voltage2.28V / Cell   (2.25 ~2.33 Selectable)
  Boost Charging Voltage2.35V/Cell
  Temperature CompensationYes

  Maximum Charging Current

  (Per Power Module)

24A (Adjustable)36A (Adjustable)54A (Adjustable)54A (Adjustable)
  PHYSICAL
  IP ClassIP20
  Dimension, D x W x H (mm)1000 x 430 x 12001000 x 430 x 12001000 x 600 x 12001000 x 600 x 1200
  Net Weight (Kgs)200200265265
  ENVIRONMENT
  Operating Temperature0-40°C
  Operating Humidity< 95 % and non-condensing
  Altitude**<1000m for Nominal power
  MANAGEMENT
  Smart RS-232/USBSupports Windows® Family, Linux and MAC
  Optional SNMPPower management from SNMP manager and web browser
  STANDARDS
  SafetyIEC/EN 62040-1
  EMCIEC/EN 62040-2 Category C3


       **  If the UPS is installed or used in a placewhere the altitude is above than 1000m, the output power must be derated one percent per 100m.

Galleon T33 10K ~ 200KVA
Galleon T33 provides better output power factor up to 1.0 with higher performance and efficiency for critical applications. It's smae as Galleon series with programmable power management outlets which can extend available battery time to critical devices by shutting down unnecessary devies. This Galleon T33 series is also suitable for laser printer and ultrasound system load.
Long press to look detail
Long by picture save/share

Galleon T33 10K ~ 200KVA

INQUIRY

enquiry form:

  • Please enter the verification code

enquiry content:


You have no items to require

Copyright @ 2021 Honyis Power Solutions Co., Ltd. All Rights Reserved

 

 粤公网安备 44030702003778号      ICP备2021024839号-1

let's chat now
添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了
粤ICP备2021024839号-1