Giant I31 industrial Online UPS 10~120KVA

Giant I31 is suitable for industrial applications and facilities because of its robustness and unique ventilation design. To increase operation reliability, Giant I31 series allowed to connect two separate power inputs.

  Main Features
  • Online double-conversion
  • DSP technology guarantees high reliability
  • Control designed to withstand all kinds of loads
  • Layered independent sealed ventilation channel design
  • Protective paints-protected circuit boards
  • Double true galvanic isolation transformer design
  • Intelligent battery management to prolong battery lifecycle 
  • Adjustable battery numbers
  • Dual-mains input design 
  • Front access makes maintenance and replacement easily
  • High short-circuit and overload capabilities
  • Ring Communication Connection, Parallel operation with up to 4 units


  MODELI31-10KLI31-15KLI31-20KLI31-30KLI31-40KLI31-60KLI31-80KLI31-100KLI31-120K
  CAPACITY10KVA/8KW15KVA/12KW20KVA/16KW30KVA/24KW40KVA/32KW60KVA/48KW80KVA/64KW100KVA/80KW120KVA/96KW
  INPUT
  Nominal Voltage3 x 380VAC (3Ph + G or 3Ph + N + G)
  Acceptable Voltage Range304VAC ~ 456VAC
  Frequency50Hz ±5 Hz (±10%)
  OUTPUT
  Nominal Voltage220VAC/230VAC/240VAC (Selectable)
  Connection TypeHardwire 3-wire (1Ph+N+G)
  WaveformPure Sine Wave
Output Voltage
Stability
  Steady state±1%
  Transient state±5%
  Frequency50 Hz
  Frequency Stability± 1%

  Frequency 

  Synchronisation Range

± 5Hz (Equal to bypass working range)

  Frequency 

  Synchronisation Speed

1~2 Hz/s
  Power Factor0.8
  Crest Factor3:1

  Total Harmonic Distortion 

  (THDv)

<2% (Linear Load)
<4% (Non-linear Load)

  Dynamic in-rush 

  Voltage Range

0%->100%->0% (R Load) <±5% : 20%->100%->20% (R Load) ±3%

  Dynamic Recovery

  Time (III Grade)

0%~100% RCD load : <60 ms recover to 90% of nominal voltage
  Phase Displacement120º ±1% (balanced load)
120º ±2% (imbalances 50% of the load)
  Transfer Time0 ms
  Overload Capability0% ~ 110% continuous running; 110% ~ 150% for 10 min~1 min; >160% for 200ms
  Short-circuit Capability60~100ms
  Transient Response Time< 5ms
  BYPASS
  Connection TypeHardwire 3-wire (1Ph+N+G)
  Input Voltage Range220VAC ± 25%

  Overload / 

  Short-circuit capability

1.5 In~1.8 In  1h~30s
1.8 In ~ >2.0 In  30s~200ms
  SYSTEM
  Efficiency (@ linear load)≥90%

  ECO Mode 

  (Non-parallel models)

Yes
  EPO FunctionYes
 BATTERY & RECTIFIER
Rectifier  Type6 pulse12 pulse

  Rated 

  Output Voltage

220 VDC
  Charger Voltage216VDC ~ 243VDC (Adjustable)

  Charging

  Current (max)

Default 10A, Maximum=Capacity / Battery Voltage

Default 10A, Maximum 40A
Battery  TypeSupport VRLA Battery
  Numbers16 - 18 pcs (adjustable)
  Reverse DiodeYes
  Cold StartYes
  PHYSICAL
  IP ProtectionIP20 (Default), IP21/IP31 (Option)
  Dimensions, DxWxH (mm)800 x 800 x 1800800 x 1200 x 1800800 x 1600 x 1800
  Net Weight (Kgs)354386400480680910101013601620
  ENVIRONMENT
  Operating Temperature

0~ 35°C continuous running, 40°C 8-hour running at nominal input voltage, recharging batteries and no overload,

 45°C derating to 85% with linear load

  Operating Humidity0~90% (non-condensing)
  Noise LevelLess than 70dB @ 1 Meter
  MANAGEMENT
  Modbus RS-232/RS485Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC
  Dry Contacts6 outputs and 2 inputs
  Optional SNMPPower management from SNMP manager and web browser
  STANDARD
  EMC/SafetyIEC 61000-4-5 Surge Protection, IEC 62040-2 EMC/EMI, IEC62040-1 Safety



  MODELI31-10KLI31-15KLI31-20KLI31-30KLI31-40KLI31-60KLI31-80KLI31-100KLI31-120K
  CAPACITY10KVA/8KW15KVA/12KW20KVA/16KW30KVA/24KW40KVA/32KW60KVA/48KW80KVA/64KW100KVA/80KW120KVA/96KW
  INPUT
  Nominal Voltage3 x 380VAC (3Ph + G or 3Ph + N + G)
  Acceptable Voltage Range304VAC ~ 456VAC
  Frequency50Hz ±5 Hz (±10%)
  OUTPUT
  Nominal Voltage220VAC/230VAC/240VAC (Selectable)
  Connection TypeHardwire 3-wire (1Ph+N+G)
  WaveformPure Sine Wave
Output
Voltage Stability
  Steady state± 1%
  Transient state± 5%
  Frequency50 Hz
  Frequency Stability± 1%

  Frequency 

  Synchronisation Range

± 5Hz (Equal to bypass working range)

  Frequency 

  Synchronisation Speed

1~2 Hz/s
  Power Factor0.8
  Crest Factor3:1

  Total Harmonic Distortion 

  (THDv)

<2% (Linear Load)
<4% (Non-linear Load)

  Dynamic in-rush

  Voltage Range

0%->100%->0% (R Load) <±5% : 20%->100%->20% (R Load) ±3%

  Dynamic Recovery

  Time (III Grade)

0%~100% RCD load : <60 ms recover to 90% of nominal voltage
  Phase Displacement120º ±1% (balanced load)
120º ±2% (imbalances 50% of the load)
  Transfer Time0 ms
  Overload Capability0% ~ 110% continuous running; 110% ~ 150% for 10 min~1 min; >160% for 200ms
  Short-circuit Capability60~100ms
  Transient Response Time< 5ms
  BYPASS
  Connection TypeHardwire 3-wire (1Ph+N+G)
  Input Voltage Range220VAC ± 25%

  Overload / 

  Short-circuit capability

1.5 In~1.8 In  1h~30s
1.8 In ~ >2.0 In  30s~200ms
  SYSTEM
  Efficiency (@ linear load)90%

  ECO Mode 

  (Non-parallel models)

Yes
  EPO FunctionYes
  BATTERY & RECTIFIER
Rectifier  Type6 pulse

  Rated 

  Output Voltage

384 VDC
  Charger Voltage395VDC ~ 435VDC (Adjustable)

  Charging

  Current (max)

Default 10A, Maximum = Capacity / Battery VoltageDefault 10A, Maximum 40A
Battery  TypeSupport VRLA Battery
  Numbers32 Pcs (29 ~ 32 pcs adjustable)
  Reverse DiodeNo
  Cold StartYes
  PHYSICAL
  IP ProtectionIP20 (Default), IP21/IP31 (Option)
  Dimensions, DxWxH (mm)800 x 800 x 1800800 x 1200 x 1800
  Net Weight (Kgs)360386400430490610680900920
  ENVIRONMENT
  Operating  Temperature

0~ 35°C continuous running, 40°C 8-hour running at nominal input voltage, recharging batteries and no overload,

 45°C derating to 85% with linear load

  Operating Humidity0~90% (non-condensing)
  Noise LevelLess than 70dB @ 1 Meter
  MANAGEMENT
  Modbus RS-232/RS485Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC
  Dry Contacts6 outputs and 2 inputs
  Optional SNMPPower management from SNMP manager and web browser
  STANDARD
  EMC/SafetyIEC 61000-4-5 Surge Protection, IEC 62040-2 EMC/EMI, IEC62040-1 Safety


Giant I31 industrial Online UPS 10~120KVA
Giant I31 is suitable for industrial applications and facilities because of its robustness and unique ventilation design. To increase operation reliability, Giant I31 series allowed to connect two separate power inputs.
Long press to look detail
Long by picture save/share
INQUIRY

enquiry form:

  • Please enter the verification code

enquiry content:


You have no items to require

Giant I31 industrial Online UPS 10~120KVA

Enquiry
INQUIRY

enquiry form:

  • Please enter the verification code

enquiry content:


You have no items to require

Copyright @ 2021 Honyis Power Solutions Co., Ltd. All Rights Reserved

 

 粤公网安备 44030702003778号      ICP备2021024839号-1

Chat Now
Chat Now
Online Contacts
Phone
+86 13352944880
Whatsapp
+86 13352944880
Wechat
+86 13352944880
Email
sales@honyis.com
粤ICP备2021024839号-1