With ingress protection of IP65 - InfiniSolar NP-LV is fully protected against dust, airborne particles whilst and water jets which makes it suitable for use both in the indoor and harsh output environment. It supports multiple input & output - split phase 208/240Vac or single phase 230Vac. InfiniSolar is also offering a second terminal for users choice as a generator input or a programmable output.
Main Features |
|
|
|
|
|
|
|
|
|
MODEL | NP-LV-6K-48V | NP-LV-10K-48V |
Phase | 120/240V Split phase, 120V/208V Split phase | 120/240V Split phase, 120V/208V Two-thirds phase |
Maximum PV Input Power | 7500W | 14500W |
Rated Output Power | 6000VA/6000W | 10000VA/10000W |
Maximum Charging Power | 6000W | 10000W |
GRID-TIE OPERATION | ||
PV INPUT (DC) | ||
Maximum DC Voltage | 600 VDC | 600 VDC |
Start-up Voltage / Initial Feeding Voltage | 120VDC / 160 VDC | 120VDC / 160 VDC |
MPP Voltage Range | 120 VDC ~ 550 VDC | 120 VDC ~ 550 VDC |
Number of MPP Trackers / Maximum Input Current | 2 / 15A | 2 / 27A |
GRID OUTPUT (AC) | ||
Nominal Output Voltage | 110 VAC (P-N) / 220 VAC (P-P) | |
Output Voltage Range | 97-132VAC(P-N) / 194VAC-264VAC(P-P) | |
Nominal Output Current | 27.3 A per phase | 41.5 A per phase |
Power Factor | 0.9 lag to 0.9 lead | |
EFFICIENCY | ||
Maximum Conversion Efficiency (DC/AC) | 96% | |
OFF-GRID OPERATION | ||
AC INPUT | ||
AC Start-up Voltage / Auto Restart Voltage | 85VAC(P-N), 170VAC(P-P) / 90VAC(P-N), 180VAC(P-P) | |
Acceptable Input Voltage Range | 85 - 140 VAC (P-N)/ 170 - 280 VAC (P-P) | |
Frequency Range | 50 Hz/60 Hz (Auto sensing) | |
Maximum AC Input Current | 30 A per phase | 50 A per phase |
PV INPUT (DC) | ||
Maximum DC Voltage | 600 VDC | |
MPP Voltage Range | 120 VDC ~ 550 VDC | |
Number of MPP Trackers / Maximum Input Current | 2 / 15A | 2 / 27A |
BATTERY MODE OUTPUT (AC) | ||
Nominal Output Voltage | 110 VAC (P-N) / 220 VAC (P-P) | |
Output Waveform | Pure sine wave | |
Efficiency (DC to AC) | 91% | 96% |
HYBRID OPERATION | ||
PV INPUT (DC) | ||
Maximum DC Voltage | 600 VDC | |
Start-up Voltage / Initial Feeding Voltage | 120VDC / 160 VDC | |
MPP Voltage Range | 120 VDC ~ 550 VDC | |
Number of MPP Trackers / Maximum Input Current | 2 / 15A | 2 / 27A |
GRID OUTPUT (AC) | ||
Nominal Output Voltage | 110 VAC (P-N) / 220 VAC (P-P) | |
Output Voltage Range | 97-132VAC(P-N) / 194VAC-264VAC(P-P) | |
Nominal Output Current | 27.3 A per phase | 41.5 A per phase |
AC INPUT | ||
AC Start-up Voltage / Auto Restart Voltage | 85VAC(P-N), 170VAC(P-P) / 90VAC(P-N), 180VAC(P-P) | |
Acceptable Input Voltage Range | 85 - 140 VAC (P-N)/ 170 - 280 VAC (P-P) | |
Maximum AC Input Current | 30 A per phase | 50 A per phase |
BATTERY MODE OUTPUT (AC) | ||
Nominal Output Voltage | 110 VAC (P-N) / 220 VAC (P-P) | |
Efficiency (DC to AC) | 91% | 96% |
BATTERY & CHARGER | ||
Nominal DC Voltage | 42-62 VDC | 80-576 VDC |
Maximum Solar Charging Current | 120 A | 50 A |
Maximum AC Charging Current | 120 A | 50 A |
Maximum Charging Current | 120 A | 50 A |
GENERAL | ||
PHYSICAL | ||
Dimension, D x W x H (mm) | 215.5 x 515 x 700 | 262 x 500 x 575 |
Net Weight (kgs) | 41 | 50 |
INTERACE | ||
Parallel Function | Yes, 6 units | |
Communication Port | RS232, RS485, WI-FI, USB | |
ENVIRONMENT | ||
Protection Degree | IP 65 | |
Operating Temperature | -25°C to 60°C (>45°C derating) |