Galleon T33 Online UPS 10~120KVA

it provides better power factor up to 0.9 with higher performance and efficiency for critical applications. it's with programmable power management outlets which can extend available battery time to critical devices by shutting down unnecessary devices.

      MODELVOLTAGEBATTERYPRICE / USDMOQLEAD TIME
      T33-10KL380/400Vac192Vdc1375.001

    3 days

    < 5 Units

      T33-20KL380/400Vac192Vdc1604.001

    3 days

    < 5 Units

      T33-30KL380/400Vac±192Vdc2257.001

    3 days

    < 5 Units

      T33-40KL380/400Vac±192Vdc2405.001

    3 days

    < 5 Units

      T33-60KL380/400Vac±192Vdc4596.001

    3 days

    < 5 Units

      T33-80KL380/400Vac±192Vdc5024.001

    3 days

    < 5 Units

      T33-100KL380/400Vac±192Vdc7223.001

    3 days

    < 3 Units

      T33-120KL380/400Vac±192Vdc8895.001

    3 days

    < 3 Units

      T33-10KL208/220Vac±961573.001

    4~5

    Weeks

      T33-15KL208/220Vac±962378.001

    4~5

    Weeks

      T33-20KL208/220Vac±962479.001

    4~5

    Weeks

      T33-30KL208/220Vac±964118.001

    4~5

    Weeks

      T33-40KL208/220Vac±964702.001

    4~5

    Weeks


Download Annex

  • Parameters
      MODELVOLTAGEBATTERYPRICE / USDMOQLEAD TIME
      T33-10KL380/400Vac192Vdc1375.001

    3 days

    < 5 Units

      T33-20KL380/400Vac192Vdc1604.001

    3 days

    < 5 Units

      T33-30KL380/400Vac±192Vdc2257.001

    3 days

    < 5 Units

      T33-40KL380/400Vac±192Vdc2405.001

    3 days

    < 5 Units

      T33-60KL380/400Vac±192Vdc4596.001

    3 days

    < 5 Units

      T33-80KL380/400Vac±192Vdc5024.001

    3 days

    < 5 Units

      T33-100KL380/400Vac±192Vdc7223.001

    3 days

    < 3 Units

      T33-120KL380/400Vac±192Vdc8895.001

    3 days

    < 3 Units

      T33-10KL208/220Vac±961573.001

    4~5

    Weeks

      T33-15KL208/220Vac±962378.001

    4~5

    Weeks

      T33-20KL208/220Vac±962479.001

    4~5

    Weeks

      T33-30KL208/220Vac±964118.001

    4~5

    Weeks

      T33-40KL208/220Vac±964702.001

    4~5

    Weeks


Main Features


• DSP technology guarantees high reliability

  DSP and MCU dual chips to secure the product reliability.

 

• Output power factor 0.9

  For critical applications, this 3-phase online UPS with output power factor 0.9 ensures higher efficiency and advanced performance.

 

• Adapting the latest Silicon carbide diodes to enhance the system efficiency

  Through adapting the latest Silicon carbide diodes, no matter it's in AC mode and battery mode, the efficiency is higher than 96%.

 

• Dual Inputs

  Galleon T33 is also available for optional dual inputs to support various inputs to have flexibility for system configuration.

 

• Very powerful charger to shorten the recharge time

  Adapting the charger rating equals to 30% of UPS capacity on 10/20Kva. Charger rating is also 20% of UPS capacity for 30Kva and above models.

 

• Adjustable charging current

  Users can adjust charging current via LCD setting based on various battery configurations.

 

• Parallel up to 6 units with common battery 

  Supports maximum 6 units in parallel with common battery pack for the parallel system.

 

• 5” color touch type LCD display

  Inbuilt 5” color touch type LCD display with 500 event/data logs.


• Optional programmable relay dry contact card

  Configurable 4 dry contact ports definition through software for various applications.

 

• Voice warning / error code notice

  Inbuilt the speaker to have human voice for the warning / error codes notice instead of traditional beeps.

 

• High overload capability

  Supporting 110% overload capacity for 60 min and up to 1 min overload condition at 150% load.

 

• Adjustable battery design

  The number of connected batteries can be adjusted flexibly based on different power demands.

 

• Dynamic password feature optimizes service performance

  This dynamic password is automatically generated from our exclusive utility tool. Each time when it is required to change service-related settings, 

  this utility tool would generate an unique password on time basis. It secures UPS from unexpected operation due to unauthorized settings.

 

• Power walk-in function

  Galleon T33 is designed to have flexible power walk-in by way of adjusting the power walk-in time. This setting will optimize generator sizing 

  and reduce the impact to the AC source by having different walk-in time period for different paralleled UPS system when AC grid is recovered.



Main Features


• DSP technology guarantees high reliability

   A Digital Signal Processor (DSP) technology digitizes the data and mathematically manipulates them to provide an improved solution with higher performance.

 

• Output power factor 1

   For critical applications, this 3-phase online UPS with output power factor 1.0 ensures higher efficiency and advanced performance.

 

• Active power factor correction in all phases

   Power factor correction is active in all phases and it can improve the efficiency of input.

 

• Dual Inputs

   Galleon T33-LV is also available for optional dual inputs to support various inputs to have flexibility for system configuration.

 

• 50Hz/60Hz frequency converter mode

   Lock output frequency at 50Hz or 60Hz to suit power sensitive equipments.

 

• ECO mode operation for energy saving

   ECO mode improves the efficiency up to 98% to cut energy usage & cost. In this mode, loads are supplied by the mains directly. 

   While mains failure, the UPS will constantly supply the power to the connected device without any interruption.

 

• Emergency power off function (EPO)

   In case of any emergency and fire, the EPO control mechanism can instantly shut down the system.

 

• Adjustable charging current

   Users can adjust charging current via LCD setting based on applications.


• Very powerful charger

   Galleon T33-LV is built-in super charger. 10K: 10A maximum, 15~20K: 20A maximum,  30K~40K: 24A maximum

   It's also support very long runtime applications when connecting to big capacity of external battery cabinet.

 

• Parallel operation with common battery

   Maximum three UPSs can be operated in parallel, increasing the capacity and performance. 

   Besides, this parallel UPS system can share common battery packs which might greatly reduce the expenseand reach the same performance.

 

• High overload capability

   Supporting 110% overload capacity for 60 min and up to 1 min overload condition at 150% load.

 

• Adjustable battery design

The number of connected batteries can be adjusted flexibly based on different power demands.This feature can allow UPS 



  MODELT33-10K (L)T33-20K (L)T33-30K (L)T33-40K (L)T33-60KLT33-80KLT33-100KLT33-120KL
  PHASE3-phase in / 3-phase out
  CAPACITY

10KVA/8KW

20KVA/16KW30KVA/27KW40KVA/36KW

60KVA/54KW

80KVA/72KW

100KVA/90KW

120KVA/108KW

  PARALLEL CAPABILITYup to 3 units in parallelup to 2 units in parallel
  INPUT
  Nominal Voltage3 x 400 VAC (3Ph+N)
  Voltage Range190-520 VAC (3-phase) @ 50% load ; 305-478 VAC (3-phase) @ 100% load208-478 VAC (3-phase) @ 70% load
305-478 VAC (3-phase) @ 100% load
  Frequency Range46~54 Hz or 56~64Hz40~70Hz
  Power Factor≧  0.99  @ 100% Load
  OUTPUT
  Output Voltage3 x 360*/380/400/415 VAC (3Ph+N)3 x 380/400/415 VAC (3Ph+N)

  AC Voltage Regulation

  (Battery Mode)

± 1%

  Frequency Range

  (Synchronized Range)

46~54Hz or 56~64Hz

  Frequency Range

  (Battery Mode)

50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
  Current Crest Ratio3:1 (max.)
  Harmonic Distortion≦2 % THD (Linear Load) ;
≦4 % THD (Non-linear Load)
≦2 % THD (Linear Load) ;
≦4 % THD (Non-linear Load)
Transfer Time

  AC Mode to

  Battery Mode

Zero
  Inverter to BypassZero
  Waveform (Battery Mode)Pure Sine wave
Overload  AC Mode100-110% for 10 min, 110-130% for 1 min, >130% for 1 second

105-110% for 1 hr, 111-125% for 10 min,

126-150% for 1 min, >150% for 200ms
  Battery Mode100-110% for 30 seconds, 110-130% for 10 seconds, >130% for 1 second105-110% for 1 hr, 111-125% for 10 min,
126-150% for 1 min, >150% for 200ms
  EFFICIENCY
  AC Mode94.0%94.0%
  ECO Mode97.0%98.0%
  Battery Mode93.5%93.0%
  BATTERY
Standard Model  Battery Type12 V / 7 Ah12 V / 7 Ah12 V / 7 Ah12 V / 9 AhN/A
  Numbers(16+16)Pcs x 1 String(16+16) Pcs x 2 Strings

  Typical

  Recharge Time

9 hours recover to 90% capacity

  Charging Current

  (max.)

1A/2A/3A/4A (Adjustable)
  Charging Voltage+/-218 VDC ± 10%
Long-run Model  Battery TypeDepending on the capacity of external batteries
  Numbers32~40 pcs (Adjustable)

  Charging Current

  (max.)

1A/2A/3A/4A (Adjustable)

Parallelable up to 3 charger 

boards to reach 12A maximum

2A/4A/6A/8A(Adjustable)

Parallelable up to 3 sets of dual charger boards to reach 24A maximum

24A32A
  Charging Voltage+/- 13.65V x N (N=16~20)+/- 13.7V x N (N = 16~20)
  INDICATORS
  LCD DisplayUPS status, Load level, Battery level, Input/Output voltage, Discharge timer,
and Fault conditions
10'' Touch Type color LCD
  PHYSICAL
Standard Model

  Dimension,

  D x W x H (mm)

781 x 250 x 750815 x 300 x 1000N/A
  Net Weight (kgs)129144225250
Long-run Model

  Dimension,

  D x W x H (mm)

781 x 250 x 750815 x 300 x 1000790 x 360 x 1010940 x 567 x 1015
  Net Weight (kgs)33486061108113199234
  ENVIRONMENT
  Operation Temperture0-40°C
  Operation Humidity< 95% and non-condersing
  Noise Level

Less than 55d

B@1 Meter

Less than 60dB @ 1 MeterLess than 70dB @ 1 Meter

Less than 60dB

@1 Meter

Less than 70dB @ 1 Meter
  MANAGEMENT
  Smart RS-232 / USBSupports Windows2  2000/2003/XP/Vista/2008, Windows2  7/8/10, Linux and MAC
  Optional SNMPPower management from SNMP manager and web browser

 

  *If output voltage is set as 3 x 360VAC, the output power of the unit will be de-rated to 90%. 



  MODELT33-LV-10K (L)T33-LV-15K(L)T33-LV-20K (L)T33-LV-30KLT33-40KL
  PHASE3-phase in / 3-phase out
  CAPACITY10KVA/10KW15KVA/15KW20KVA/20KW30KVA/30KW40KV/40KW
  INPUT
  Nominal Voltage3 x 208/220 VAC (Ph-Ph)
3 x 120/127 VAC (Ph-N)
  Voltage Range

138~270 VAC (3-phase) @ 50% load; 173~253 VAC (3-phase) @ 100% load

 80~156 VAC (Ph-N) @ 50% load ; 100~146 VAC (Ph-N) @ 100% load

  Frequency Range46~54 Hz or 56~64Hz
  Power Factor≧  0.99  @ 100% Load
  OUTPUT
  Output Voltage3 x 208/220 VAC (Ph-Ph)
3 x 120/127 VAC (Ph-N)
  AC Voltage Regulation (Batt. Mode)± 1%
  Frequency Range (Synchronized Range)46~54Hz or 56~64Hz
  Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
  Current Crest Ratio3:1 (max.)
  Harmonic Distortion≦ 2 % THD (Linear Load) ;
≦ 4 % THD (Non-linear Load PF≥0.8)
Transfer Time  AC Mode to Batt. ModeZero
  Inverter to BypassZero
  Waveform (Batt. Mode)Pure Sine wave
Overload  AC Mode100-110% for 1 hr, 110-130% for 1 min, >130% for 1 second
  Battery Mode100-110% for 30 seconds, 110-130% for 10 seconds, >130% for 1 second
  EFFICIENCY
  AC Mode93%
  ECO Mode97%
  Battery Mode92.5%
  BATTERY
Standard Model  Battery Type12 V/9 Ah12 V/9 Ah12 V/9 Ah12 V/7 Ah12 V/9 Ah
  Numbers

(10+10)pcs x 1 string 

Optional max. 2 strings

(10+10)pcs x 2 strings 

Optional max. 3 strings

(10+10)pcs x 3 stringsN/A
  Typical Recharge Time9 hours recover to 90% capacity
  Charging Current (max.)1A/2A/3A/4A (Adjustable)
  Charging Voltage+/-136.5 VDC ± 10%
Long-run Model  Battery TypeDepending on the capacity of external batteries
  Numbers16~20 pcs (Adjustable)
  Charging Current (max.)

4A/8A/12A(Adjustable)

 Max. 12A

4A/8A/12A (Adjustable)

 Parallelable up to 20A (Optional)

4A/8A/12A/16A (Adjustable)

 Parallelable up to 24A (Optional)

  Charging Voltage+/-13.65V*N  (N = 8~10)
  INDICATORS
  LCD DisplayUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
  PHYSICAL
Standard Model  Dimension,DxWxH (mm)667 x 250 x 827865 x 300 x 1020N/A
  Net Weight (kgs)95181231
Long-run Model  Dimension,DxWxH (mm)667 x 250 x 827865 x 300 x 1020790 x 420 x 1200
  Net Weight (kgs)458081150160
  ENVIRONMENT
  Operation Temperture0-40°C
  Operation Humidity< 95% and non-condersing
  Noise Level

Less than 60dB

 @ 1 Meter

Less than 70dB @1 Meter

Less than 75dB

@ 1 Meter

  MANAGEMENT
  Smart RS-232 / USBSupports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux and MAC
  Optional SNMPPower management from SNMP manager and web browser


  *If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated 1% per 100m.



Galleon T33 Online UPS 10~120KVA
it provides better power factor up to 0.9 with higher performance and efficiency for critical applications. it's with programmable power management outlets which can extend available battery time to critical devices by shutting down unnecessary devices.
Long press to look detail
Long by picture save/share
INQUIRY

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

enquiry content:


You have no items to require

Galleon T33 Online UPS 10~120KVA

Enquiry
INQUIRY

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

enquiry content:


You have no items to require

Copyright @ 2021 Honyis Power Solutions Co., Ltd. All Rights Reserved

 

 粤公网安备 44030702003778号      ICP备2021024839号-1

Chat Now
Chat Now
Online Contacts
Phone
+86 13352944880
Whatsapp
+86 13352944880
Wechat
+86 13352944880
Email
sales@honyis.com