Our total power solution integrates UPS power system, IT power distribution, air-conditioning power distribution, lighting power distribution, STS, and UPS input/output power distribution, into one cabinet. the modularized architecture helps improve the availability and reduce the engineering cost significantly while providing reliable, pure and uninterrupted power for your business.
Main Features |
|
|
|
|
|
|
|
|
MODEL | APlus-PDU M33-20-40KL | APlus-PDU M33-30-60KL | APlus-PDU M33-20-80KL | APlus-PDU M33-30-120KL | APlus-PDU M33-30-180KL | |
PHASE | 3-phase in/3-phase out | |||||
MAX CABINET CAPACITY* | 40KW | 60KW | 80KW | 120KW | 180KW | |
BATTERY TYPE | External Battery | |||||
ONE POWER MODULE CAPACITY | 20KVA / 20KW | 30KVA / 30KW | 20KVA / 20KW | 30KVA / 30KW | 30KVA / 30KW | |
MAX. POWER MODULE NUMBER | 2 | 4 | 4 | 6 | ||
INPUT | ||||||
Nominal Voltage | 3 x 380VAC/400VAC/415VAC (3Ph+N) | |||||
Voltage Range | 305 ~ 478 VAC at 70% - 100% load; 208 ~ 478 VAC for <70% load | |||||
Nominal Frequency | 50/60Hz (Auto sensing) | |||||
Frequency Range | 40Hz ~70Hz | |||||
Power Factor | > 0.99 at 100% load, >0.98 at 50% load | |||||
Harmonic Distortion (THDi) | < 3% @ 100% load | |||||
OUTPUT | ||||||
Nominal Voltage | 3 x 380VAC/400VAC/415VAC (3Ph+N) | |||||
Voltage Regulation (Steady state) | ≦ ± 1% Typical (balanced load) ; ≦ ± 2% Typical (unbalanced load) | |||||
Nominal Frequency | 50/60Hz | |||||
Frequency Range (Synchronized) | 46Hz ~ 54Hz or 56Hz ~ 64Hz | |||||
Overload Capability | 1 hour for 110%, 10 mins for 125% ; 1 min for 150% and 200ms for >150% | |||||
Harmonic Distortion | ≦ 2% THD (Linear Load) ; ≦ 4% THD (Non-linear Load) | |||||
Efficiency | Up to 94.5% | |||||
BATTERY / CHARGER | ||||||
Nominal Voltage | +/- 216V (12V x 36 Pcs) | |||||
Maximum Voltage | +/- 240V (12V x 40 Pcs) | |||||
Minimum Voltage | +/- 192V (12V x 32 Pcs) | |||||
Float Charging Voltage | 2.25V/Cell | |||||
Boost Charging Voltage | 2.35V/Cell | |||||
Temperature Compensation | Yes | |||||
Maximum Charging Current | 16A | 32A | 32A | 48A | ||
PHYSICAL | ||||||
Cabinet Dimension (D x W x H) mm | 850 x 490 x 525 | 850 x 490 x 792 | 850 x 490 x 792 | 850 x 490 x 1104 | ||
ENVIRONMENT | ||||||
Operating Temperature | 0 ~ 40°C | |||||
Relative Humidity | 0 ~ 95% non-condensing | |||||
Altitude | <1000m for Nominal power | |||||
IP Protection | IP 20 | |||||
MANAGEMENT | ||||||
Smart RS-232 / USB | Supports Windows® Family, Linux and MAC | |||||
Optional SNMP | Power management from SNMP manager and web browser | |||||
STANDARDS | ||||||
Safety | IEC/EN 60950-1; IEC/EN 62040-1 | |||||
EMC | IEC/EN 62040-2 Category C3 |
* When temperature is above 30°C, the output power factor will be de-rated, 0.9 at 31°C~35°C and 0.8 at 36°C~40°C.
** If the UPS is installed or used in a placewhere the altitude is above than 1000m, the output power must be derated one percent per 100m.