WIth true double-conversion design, Galleon T11 Pro series provides power full and overall protection to your sensitive devices. It can accept wider input voltage for harsh environment. Its perfect prtection for your precious servers and workstations. For Galleon T11 Pro with cTUVus, please check with our sales.
Main Features ( 1KVA / 2KVA / 3KVA ) | ||||
| ||||
| ||||
| ||||
| ||||
| ||||
| ||||
| ||||
| ||||
| ||||
| ||||
| ||||
|
Main Features ( 6KVA / 10KVA ) | ||||
| ||||
| ||||
| ||||
| ||||
| ||||
| ||||
| ||||
| ||||
| ||||
| ||||
| ||||
| ||||
| ||||
|
MODE | T11-1K(L) Pro | T11-2K(L) Pro | T11-3K(L) Pro | |||
PHASE | Single phase with ground | |||||
CAPACITY * | 1000 VA / 1000 W | 2000 VA / 2000 W | 3000VA / 3000W | |||
INPUT | ||||||
Nominal Voltage | 200*/208*/220/230/240 VAC | |||||
Input Voltage Range | 110 ~ 300 VAC (Based on load at 50%) 160 ~ 300 VAC (Based on load at 100%) | |||||
Frequency Range | 40 Hz ~ 70 Hz | |||||
Power Factor | ≧ 0.99 @ nominal voltage (100% load) | |||||
THDi | ≦ 5% @ nominal voltage (100% load) | |||||
OUTPUT | ||||||
Output Voltage | 200*/208*/220/230/240 VAC | |||||
AC Voltage Regulation (Battery Mode) | ± 1 % | |||||
Frequency Range (Synchronized Range) | 50Hz system:47 ~ 53 Hz (60Hz system:57~63Hz) | |||||
Frequency Range (Battery Mode) | 50 Hz ± 0.1 Hz(60Hz ± 0.1 Hz) | |||||
Current Crest Ratio | 3:1 | |||||
Harmonic Distortion | ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) | |||||
Transfer Time | AC to DC | Zero | ||||
Inverter to Bypass | 4 ms (Typical) | |||||
ECO to Battery mode | 8 ms (Typical), 10 ms(max) | |||||
Waveform (Battery Mode) | Pure Sinewave | |||||
EFFICIENCY | ||||||
ECO mode @ full charged battery | 96% | 97% | ||||
AC Mode @ full charged battery | 92% max. | 93% max. | 94% max. | |||
Battery Mode | 88% max. | 89% max. | 88% max. | 89% max. | 91% max. | |
BATTERY | ||||||
Standard Model | Battery Type | 12 V / 9 Ah | 12 V / 7 Ah | 12 V / 9 Ah | 12 V / 7 Ah | 12 V / 9 Ah |
Numbers | 2 | 3 | 4 | 6 | 6 | |
Typical Recharge Time | 4 hours recover to 90% capacity for internal battery | |||||
Charging Current (CC) | 1 A | |||||
Charging Voltage (FV) | 27.4VDC ± 1% | 41.0VDC ± 1% | 54.8VDC ± 1% | 82.2VDC ± 1% | 82.2VDC ± 1% | |
Long-run Model | Battery Type and Numbers | 12V x 2 pcs | 12V x 3 pcs | 12V x 4 pcs | 12V x 6 pcs | 12V x 6 pcs |
Charging Current (max.) | 6A (1A/2A/4A/6A adjustable by Jumper) | |||||
Charging Voltage | 27.4VDC ± 1% | 41.0VDC ± 1% | 54.8VDC ± 1% | 82.2VDC ± 1% | 82.2VDC ± 1% | |
INDICATORS | ||||||
LCD | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicator Via LCD | |||||
PHYSICAL | ||||||
Standard Model | Dimension, D x W x H (mm) | 282 x 145 x 220 | 397 x 145 x 220 | 435 x 145 x 220 | 421 x 190 x 318 | 421 x 190 x 318 |
Net Weight (kgs) | 9.8 | 13.9 | 17 | 24.2 | 27.6 | |
Long-run Model | Dimension, D x W x H (mm) | 282 x 145 x 220 | 397 x 145 x 220 | |||
Net Weight (kgs) | 4.1 | 6.8 | 7.4 | |||
ENVIRONMENT | ||||||
Humidity | 20-95 % RH @ 0 - 40°C (non-condensing) | |||||
Noise Level | Less than 50dBA @ 1 Meter with Fan speed control | |||||
MANAGEMENT | ||||||
Smart RS-232 or USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC | |||||
Optional external Slot (for SNMP, Dry contact, …) | Power management from SNMP manager and web browser | |||||
STANDARD | ||||||
EMC/Safety | CE (EMC: EN62040-2 C2) |
MODEL | T11-6K(L) Pro | T11-10K(L) Pro | |||
PHASE | 1 phase in / 1 phase out | ||||
CAPACITY | 6000 VA / 6000 W | 10000 VA / 10000 W | |||
INPUT | |||||
Nominal Voltage | 208/220/230/240 VAC | ||||
Voltage Range | 110~300VAC ± 3 % at 50% load ; 176~300VAC ± 3 % at 100% load | ||||
Frequency Range | 46~54 Hz or 56~64 Hz 40 ~70 Hz (In generator mode) | ||||
Power Factor | ≧ 0.99 @ full load | ||||
THDi | < 4% @100% Load ; < 6% @50% Load | ||||
OUTPUT | |||||
Output Voltage | 208*/220/230/240 VAC | ||||
AC Voltage Regulation (Battery Mode) | ± 1% | ||||
Frequency Range (Synchronized Range) | 46~54 Hz or 56~64 Hz | ||||
Frequency Range (Battery Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||||
Current Crest Ratio | 3:1 (max.) | ||||
Harmonic Distortion | ≦ 1 % THD (Linear Load) ; ≦ 4 % THD (Non-linear Load) | ||||
Transfer Time | AC Mode to Batt. Mode | Zero | |||
Inverter to Bypass | Zero | ||||
Waveform (Battery Mode) | Pure Sinewave | ||||
Overload | AC Mode | 100-105% Continue, 105-125% for 10 min, 125%~150% 0.5min, >150% immediately | |||
Battery Mode | 100-110% 3min, 110-130% for 0.5 min, >130% immediately | ||||
EFFICIENCY | |||||
AC Mode | 94% | ||||
Battery Mode | 92% | ||||
BATTERY | |||||
Standard Model | Battery Type | 12 V / 7 Ah | 12 V / 9 Ah | ||
Numbers | 16 | 20 | 16 | 20 | |
Typical Recharge Time | 9 hours recover to 90% capacity | ||||
Charging Current (max.) | 1.0 A | ||||
Charging Voltage | 218.4 VDC ± 1% | 240 VDC ± 1% | 218.4 VDC ± 1% | 240 VDC ± 1% | |
Long-run Model | Battery Type | Lead Acid or optional Lithium battery | |||
Numbers | 16-20** | ||||
Charging Current (max.) | 1A/2A/4A/6A/8A | ||||
Charging Voltage | Lead Acid Batery: (13.65VDC x battery number) ± 1% Lithium Battery: 192~240VDC settable | ||||
INDICATORS | |||||
LCD Display | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | ||||
PHYSICAL | |||||
Standard Model | Dimension,DxWxH (mm) | 442 x 190 x 688 | 442 x 190 x 688 | ||
Net Weight (kgs) | 51.5 | 60.5 | 60 | 70 | |
Long-run Model | Dimension,DxWxH (mm) | 435 x 145 x 238 | |||
Net Weight (kgs) | 8.6 | 9.7 | |||
ENVIRONMENT | |||||
Operating Humidity | 20-95 % RH @ 0- 40°C (Non-condensing) | ||||
Noise Level | Less than 55dB @1Meter | Less than 58dB @1Meter | |||
MANAGEMENT | |||||
Smart RS-232/USB | Supports Windows® Family, Linux and MAC | ||||
Optional SNMP | Power management from SNMP manager and web browser |