Embedded with isolated transformer, Giant G33 will eliminate common mode noise and the need to install expensive dedicated circuits. it provides reliable galvanically isolated power to critical equipment.
Main Features |
|
|
|
|
|
|
|
|
|
|
|
|
MODEL | G33-10KL | G33-15KL | G33-20KL | G33-30KL | G33-40KL | G33-60KL | G33-80KL | G33-100KL | G33-120KL | G33-160K | G33-200KL | |
CAPACITY | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW | 60KVA/48KW | 80KVA/64KW | 100KVA/80KW | 120KVA/96KW | 160KVA/128KW | 200KVA/160KW | |
INPUT | ||||||||||||
Nominal Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||||||||
Acceptable Voltage Range | 285VAC ~ 475VAC | |||||||||||
Frequency | 50/60 Hz ± 10 % | |||||||||||
INVERTER | ||||||||||||
Nominal Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||||||||
Precision | Stationary: ±1%; Transitory: ±5% (load variations 100-0-100%) | |||||||||||
Frequency | 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz | |||||||||||
Max. Synchronization Speed | ±1 Hz/s | |||||||||||
Waveform | Pure Sinewave | |||||||||||
Total Harmonic Distortion (THDv) | <2% (Linear Load) ; <5% (Non-linear Load) | |||||||||||
Phase Displacement | 120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load) | |||||||||||
Dynamic Recovery Time | 3 cycles at 90 % of the static value | |||||||||||
Admissible Overload | 110% ~ 150% 10 min ~ 60 sec ; 150% ~ 160% 60 sec~ 200ms ; >160% 200ms | |||||||||||
Admissible Crest Factor | 3:1 | |||||||||||
Admissible Power Factor | 0.6~1 (inductive or capacitive) | |||||||||||
Imbalance Output Voltage @ 100% Unbalanced Load | <1% | |||||||||||
Current Limit | High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit | |||||||||||
STATIC BYPASS | ||||||||||||
Type | Solid state | |||||||||||
Voltage | 176VAC ~ 264VAC (Ph-N) ; 304VAC ~ 456VAC (Ph-Ph) | |||||||||||
Frequency | 50/60 Hz ± 10 % | |||||||||||
Activation Criterion | Microprocessor control | |||||||||||
Transfer Time | Zero | |||||||||||
Admissible Overload | 0% ~ 150% continuous working ; 150% ~ 180% 60 min~5 min ; >180% 5 min | |||||||||||
Transfer to Bypass | Immediate, for overloads above 160% | |||||||||||
Retransfer | Automatic after alarm clear | |||||||||||
MAINTENANCE BYPASS | ||||||||||||
Type | Without interruption | |||||||||||
Voltage | 3 x 400V (3Ph + N) | |||||||||||
Frequency | 50/60 Hz | |||||||||||
Overall Efficiency | Line Mode | 89% | 90% | 91% | 92% | |||||||
Battery Mode | 90% | 91% | 92% | 93% | ||||||||
BATTERY & CHARGER | ||||||||||||
Battery Type and Numbers | 12VDC x 32 pcs (29~32 pcs adjustable) | |||||||||||
Nominal Battery Voltage | 384 VDC (Based on 32pcs batteries) | |||||||||||
Charging Method | CC/CV | |||||||||||
Precision | ±1% | |||||||||||
Charging Current | Default 10A, *Maximum=Capacity(KW)/Battery (real-time). | Default 10A; Maximum 40A; 5A@ full load | ||||||||||
Charging Voltage | 432 VDC (Based on 32pcs batteries) | |||||||||||
PHYSICAL | ||||||||||||
Dimensions, D x W x H (mm) | 656x405x817 | 656x405x941 | 821x432x1159 | 975x554x1286 | 975x554x1326 | 1051x705x1646 | ||||||
Net Weight (Kgs) | 118 | 120 | 145 | 193 | 278 | 365 | 471 | 573 | 650 | 760 | 790 |
* The maximum current is never higher than 40A.