Giant iND is a 3-Phase Online UPS with IP31-rated protection and outstanding heat dissipation performance for industrial and harsh environments by applying advanced graphene coating Hi-tech components. Moreover, Giant iND designed with a patented chassis structure offers 100% front access to allow easy maintenance and wiring for input, output, and periodically replacing components.
Main Features |
|
|
|
|
|
|
|
|
|
|
|
MODEL | I33-10KL | I33-20KL | I33-30KL | I33-40KL | I33-60KL | I33-80KL | I33-100KL | I33-120KL | I33-160KL |
CAPACITY | 10KVA / 9KW | 20KVA / 18KW | 30KVA / 27KW | 40KVA / 36KW | 60KVA / 54KW | 80KVA / 72KW | 100KVA / 90KW | 120KVA / 108KW | 160KVA / 144KW |
INPUT | |||||||||
Rectifier Type | 6 pulse | 12 pulse | |||||||
Main Input and Bypass Input | Supports dual inputs | ||||||||
Nominal Voltage | 380VAC/400VAC/415VAC | ||||||||
Acceptable Voltage Range | 304VAC ~ 456VAC | ||||||||
Frequency | 50Hz/60Hz ± 10% | ||||||||
TVSS | 40kA | ||||||||
BYPASS | |||||||||
Nominal Voltage | 380VAC/400VAC/415VAC | ||||||||
Input Voltage Range | 285VAC ~ 475VAC | ||||||||
BATTERY | |||||||||
Battery Voltage | 384 VDC (Adjustable) | ||||||||
Cold Start | Yes | ||||||||
OUTPUT | |||||||||
Power Factor | 0.9, customized up to 1.0 | ||||||||
Nominal Output Voltage | 380VAC/400VAC/415VAC | ||||||||
Output Voltage Regulation | ±1% | ||||||||
Frequency | 50Hz/60Hz ± 1% | ||||||||
Overload Capability | 110% continuous running; 125% for 10 min; >150% for 1 min | ||||||||
PHYSICAL | |||||||||
IP Protection | IP31 (default), IP42 (optional) | ||||||||
Dimensions,DxWxH(mm) | 800 x 800 x 1800 | 800 x 1200 x 1800 | 800 x 1600 x 1800 | ||||||
Net Weight (Kgs) | 349 | 385 | 427 | 508 | 563 | 760 | 850 | 1120 | 1390 |
ENVIRONMENT | |||||||||
Operating Temperature | 0~ 40°C | ||||||||
Storage Temperature | -25°C ~ 55°C | ||||||||
Humidity | 0~95% (non-condensing) | ||||||||
Altitude | 1000m | ||||||||
MANAGEMENT | |||||||||
Modbus RS-232/RS485 | Supports Windows® family, Linux and MAC | ||||||||
Dry Contacts | 5 outputs and 4 inputs | ||||||||
Optional SNMP | Power management from SNMP manager and web browser | ||||||||
STANDARD | |||||||||
Safety | IEC62040-1-2017 | ||||||||
EMC Immunity | IEC61000-4-5 | ||||||||
EMC Emissions | IEC62040-2-2018 | ||||||||
Approvals | CE / CB/ Conformance testing / EMC / ROHS2 / Reach / YDT1095-2018 |