Otima Tower 800VA ~ 5000VA

Rating from 800VA to 5000VA, Otima provides server-grade full power protection from power failure, spikes and surge in small footprint with powerful output power factor 0.9. This series is perfect for networking, telecom, server and mission-critical applications.

  Main Features
  • Pure sine wave
  • Output power factor 0.9
  • Programmable power management outlets
  • ECO (Efficiency Corrective Optimizer) operation for energy saving
  • Very high efficiency in battery mode
  • Boost and Buck AVR for voltage stabilization
  • Multiple communications available
  • 3-stage smart battery charging control
  • Optional HID Power Device USB Port



  MODELOtima T800Otima T1100Otima T1500Otima T2000Otima T2500Otima T3000Otima T5000
  CAPACITY800VA / 720W1100VA / 990W1500VA / 1350W2000VA / 1800W2500VA / 2250W3000VA / 2700W5000VA / 4500W
  INPUT
  Voltage110/115/120/127 VAC or 208/220/230/240 VAC208/220/230/240VAC
  Acceptable Voltage Range81-152 VAC or 162-290 VAC162-290 VAC
  Frequency Range60/50 Hz (Auto sensing)
  OUTPUT
  Output Voltage110/115/120/127 VAC or 208/220/230/240 VAC208/220/230/240VAC
  Voltage Regulation (Battery Mode)±1.5 % (Before battery alarm)
  Frequency Range (Battery Mode)50 Hz or 60 Hz ± 1 Hz
  Current Crest Ratio3:1
  Harmonic Distortion2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm)
  Transfer TimeTypical 2-6 ms, 10ms max.
  Waveform (Battery Mode)Pure Sinewave
  EFFICIENCY
  ECO Mode97%
  Buck & Boost Mode95%
  Battery Mode

≧ 88%, up to 90%

 @ nominal battery voltage

≧89%, up to 91%

 @ nominal battery voltage for 110/115/120/127 VAC

≧91%, up to 92% 

@ nominal battery voltage for 208/220/230/240 VAC

≧91%, up to 92% 

@ nominal battery voltage

  BATTERY
  Type & Number12 V/7 Ah x 212 V/9 Ah x 212 V/7 Ah x 412 V/9 Ah x 412 V/7 Ah x 612 V/9 Ah x 612 V/10 Ah x 6
  Charging Current (max.)1.5 A
  Charging Voltage27.4 VDC ± 1%54.8 VDC ± 1%82.1 VDC ± 1%
  Typical Recharge Time4 hours recover to 90% capacity
  PROTECTION
  Full ProtectionOverload, discharge, and overcharge protection
  INDICATORS
  LCD DisplayAC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault and Low Battery
  ALARM
  Battery ModeSounding every 10 seconds
  Low BatterySounding every 2 seconds
  OverloadSounding every second
  FaultContinuously sounding
  PHYSICAL
  Dimension,DxWxH(mm)397 x 145 x 220455 x 145 x 220421 x 190 x 318
  Net Weight (kgs)11.712.117.219.727.72934.5
  ENVIRONMENT
  Humidity0-90 % RH @ 0- 40°C (Non-condensing)
  Noise LevelLess than 45dB
  Altitude0~3000m, 10% de-rating for over 1000m
  MANAGEMENT
  Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC
  Optional SNMPPower management from SNMP manager and web browser


Otima Tower 800VA ~ 5000VA
Rating from 800VA to 5000VA, Otima provides server-grade full power protection from power failure, spikes and surge in small footprint with powerful output power factor 0.9. This series is perfect for networking, telecom, server and mission-critical applications.
Long press to look detail
Long by picture save/share
INQUIRY

enquiry form:

  • Please enter the verification code

enquiry content:


You have no items to require

Add Successfully

Otima Tower 800VA ~ 5000VA

Enquiry
INQUIRY

enquiry form:

  • Please enter the verification code

enquiry content:


You have no items to require

Add Successfully

Copyright @ 2021 Honyis Power Solutions Co., Ltd. All Rights Reserved

 

 粤公网安备 44030702003778号      ICP备2021024839号-1

Copyright @ 2022 

Honyis Power Solutions Co., Ltd.

All Rights Reserved

 

 粤公网安备 44030702003778号      

ICP备2021024839号-1

 

let's chat now
添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了
粤ICP备2021024839号-1