enquiry form:
enquiry content:

You have no items to require
With new invented digitalized PWM-based controller, Prosine UPS simplifies traditional circuit structure to digital controlled pure output sine wave. The new system is specifically designed to protect mini servers, gaming P, critical data loaded computer and point of sale (POS) systems against damaging power disturbances, especially for the servers with active PFC power supply. Besides, we offer free management software to remotely manage and monitor the UPS through a web browser easily. it make
Main Features |
|
|
|
|
|
|
|
MODEL | Prosine 600 | Prosine 800 |
CAPACITY | 600 VA / 360 W | 800 VA / 480 W |
INPUT | ||
Voltage | 110/120 VAC or 220/230/240 VAC | |
Voltage Range | 81-145 VAC / 162-290 VAC | |
Frequency Range | 60/50 Hz (Auto sensing) | |
OUTPUT | ||
AC Voltage Regulation (Battery Mode) | ±10% | |
Frequency Range (Battery Mode) | 50 Hz or 60 Hz ± 1 Hz | |
Transfer Time | Typical 2-6 ms, 10ms max. | |
Waveform (Battery Mode) | Pure Sinewave | |
BATTERY | ||
Battery Type & Number | 12 V / 7Ah x 1 | 12 V / 9Ah x 1 |
Typical Recharge Time | 4 hours recover to 90% capacity | |
PROTECTION | ||
Full Protection | Overload, discharge, and overcharge protection | |
INDICATORS | ||
LCD Display | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery | |
ALARM | ||
Battery Mode | Sounding every 10 seconds | |
Low Battery | Sounding every second | |
Overload | Sounding every 0.5 second | |
Battery Replacement Alarm | Sounding every 2 seconds | |
Fault | Continuously sounding | |
PHYSICAL | ||
Dimension, D x W x H (mm) | 328 x 100 x 145 | |
Net Weight (kgs) | 5.2 | 6.0 |
ENVIRONMENT | ||
Humidity | 0-90 % RH @ 0- 40°C (Non-condensing) | |
Noise Level | Less than 40dB | |
MANAGEMENT | ||
USB & RS-232 Ports | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC |